X-Ray Test Device Victoreen ® Model 4000M+

Please Call 01761 417402 to order

Manufacturer: FLUKE 
Price (Excl. VAT): £ 0.00
VAT: £ 0.00
Price: £ 0.00
The Victoreen ® X-Ray Test Device, Model 4000M+ does it all. Simply place the instrument in the x-raybeam, make one exposure, and it serially displays kVp Maximum, kVp Average, kVp Effective, dose, and time. The Model 4000 M then automatically resets for the next exposure. A CsI photodiode pair provide the kVp measurements through five user-selectable filter pairs. This ensures optimum accuracy over the entire diagnostic range with minimum filtration dependence. Exposure measurements are made with a parallel plate ionization chamber located above the filter wheel. Exposure time is measured with quartz crystal accuracy. Plus, avariety of external ion chambers may be connected for even greater flexibility.

Features
  • Measures kVp maximum, kVp average, kVp effective, dose and time in one exposure.
  • Compact, lightweight design
  • Displays R or Gy
  • External ion chambers for Mammo, CT, imageintensifier and phototiming measurements.
  • Automatic exposure reset for hands - off operation
  • Rechargeable Ni-Cd batteries provide more than six hours of continuous service
  • RS-232 computer interface
  • Storage scope output for real-time waveform display
  • Reversible display for fluoro measurements

Downloads


Download File

Downloads


Download File
Kilovoltage
Accuracy 1kV Mo/Mo (22 to 35kVp) (Mammo generators w/30 µ Mo)
Range W/Al Tubes: 27 to 155kVp. Mo/Mo Tubes: 21 to 50kVp
Time Measured during entire exposure at 90% rise/fall of wave form
Accuracy Within 2% or 2 ms, whichever is greater
Range 1ms to 10 seconds
Fluoroscopic rate
Measured over one second intervals during fluoro exposure
Accuracy ±5%
Range 0.5 to 200R/min
Detectors
kV CsI/photodiode pair measures x-ray transmission through differential attenuators
Time Computed from kV waveform stored in memory against quartz crystal time base
Exposure Parallel plate ionization chamber
Volume 36cm3
Window 38mg/cm3, 18.9cm3 polycarbonate
Calibration Reference to a NIST traceable voltage divider and a calibrated exposure monitor during irradiation